The Ideal Vogue Max Combi 26 is a 26 kW A-rated gas combi boiler, introduced in 2019, offering 10.65 litres per minute DHW flow and 93% seasonal efficiency.
The Ideal Vogue Max Combi 26 is a natural gas condensing combi boiler designed for domestic heating and hot water in UK properties. Introduced in 2019, this wall-hung appliance is suitable for engineers requiring detailed specifications, fault-finding guidance, and installation parameters. It serves as a reference for both installation and ongoing maintenance for gas-safe professionals and provides homeowners with essential product insights.
Stick a QR tag on the case, scan it on every service and give your customer a permanent, shareable service history they can pull up from any phone.
Permanent, shareable service history
One QR scan on the boiler surfaces every previous fault, part change and visit — no paperwork to dig out.
Free AI fault diagnostics, built in
Every tag you fit unlocks the AI diagnostic tool for that exact model — paste a fault code, get a ranked cause list.
Your name on the boiler forever
When the next service or breakdown comes around the homeowner scans and sees your number first.
First 12 BoilerTags are free
Tag every install and service you do from now on — the subscription only kicks in once you scale past your first dozen.
Diagnosing a fault on a Ideal Vogue Max Combi 40 right now?
Try the free AI fault diagnostics tool — no signup needed.
Full technical specifications extracted from the manufacturer brochure. Empty sections are hidden.
standard configuration of pipework from the boiler is routed downwards
Hard water areas require scale reducing device; water treatment recommended.
The Ideal Vogue Max Combi 26 is a high-efficiency natural gas combi boiler, delivering a maximum central heating output of 18 kW and domestic hot water output of 26 kW. It achieves a seasonal efficiency of 93% and holds an ErP A-rating for both heating and hot water. The boiler provides a DHW flow rate of 10.65 litres per minute at a 35°C temperature rise, making it suitable for typical UK household demands. Its compact dimensions (740mm H x 445mm W x 330mm D) and dry weight of 32.4 kg facilitate installation in various domestic settings. The unit features a stainless steel primary heat exchanger and is Boiler Plus compliant, supporting OpenTherm controls for enhanced system efficiency.
Every fault code listed in the manufacturer brochure, with likely causes and engineer actions. Each code has a permalink — paste a URL like https://www.boilertag.com/boilers/ideal/vogue-max-combi-40#fault-overheat lockout to jump straight to the entry.
| Code | Meaning | Details |
|---|---|---|
| OVERHEAT LOCKOUTLockout | Overheat Lockout Show causes & actionsLikely causes
Engineer action Restart Boiler Fill and vent the system and open all Isolation Valves, then Restart the Boiler Check the Flow and Return Thermistors (refer to Sections 4.7 & 4.9) Replace the Pump, then Restart the Boiler | Details |
| IGNITION LOCKOUTLockout | Ignition Lockout Show causes & actionsLikely causes
User action Check other gas appliances work If pre-payment meter check credit If not, contact gas supplier Restart boiler. Engineer action Check the Detection Electrode and associated Harness for continuity, visual condition and position (refer to Section 3.16). Check if the Condensate Pipe is Blocked. Check Gas Supply and rectify fault Check wiring from Gas Valve to PCB and replace if necessary, otherwise replace the main PCB Replace Gas Valve Replace Spark Generator and Harness as necessary Replace Ignition Electrode and associated Harness as necessary Replace Gas Valve | Details |
| FLAME LOSS | Flame Loss Show causes & actionsLikely causes
Engineer action Check the Detection Electrode and associated Harness for continuity, visual condition and position. Check if the Condensate Pipe is blocked. Check if the Flue is blocked. Replace as necessary Check Gas Supply and rectify fault Check wiring from Gas Valve to PCB and replace if necessary, otherwise replace the main PCB Replace Spark Generator and Harness as necessary Replace Ignition Electrode and associated Harness as necessary Replace Gas Valve | Details |
| THERMAL FUSE LOCKOUTLockout | Thermal Fuse Lockout Show causes & actionsLikely causes
User action Press RESTART, then power cycle the boiler. Engineer action Replace the primary PCB Replace the wiring from the PCB to the thermal fuse Replace the heat exchanger | Details |
| TOO MANY RESETS | Too Many Resets Show causes & actions5 Restarts within 15 minutes User action Turn power off and on | Details |
| FLAME ON BEFORE GV ON | Flame On before Gas Valve On Show causes & actionsLikely causes
Engineer action Check integrity of wiring from primary PCB to Flame Sense electrode, replace if deteriorated. Check condition of Flame Sense Electrode and replace if deteriorated Replace Flame Detection Electrode Replace wiring from primary PCB to flame sense electrode | Details |
| FLOW THERMISTOR FAULT | Flow Thermistor Fault Show causes & actionsLikely causes
Engineer action Fit a new thermistor Replace wiring from flow thermistor to primary PCB Replace primary PCB | Details |
| OUTSIDE SENSOR FAULT | Outside Sensor Fault Show causes & actionsLikely causes
Engineer action Securely connect the wiring at both the boiler and Outside Sensor Fit a new outside sensor Ensure the wiring has continuity and is securely connected Replace main PCB | Details |
| RETURN THERMISTOR FAULT | Return Thermistor Fault Show causes & actionsLikely causes
Engineer action Fit a new thermistor Replace wiring from flow thermistor to primary PCB Replace primary PCB | Details |
| FAN FAULT | Fan Fault Show causes & actionsLikely causes
Engineer action Rectify wiring & connections Replace main PCB Replace Fan | Details |
| LOW WATER PRESSURE | Low Water Pressure Show causes & actionsLikely causes
User action With boiler off & system cold fill system to between 1.0 & 1.5 bar (Press PICTURE to see how) Bleed radiators then refill If fault persists contact Ideal (01482 498660) If pressure loss re-occurs contact installer Engineer action Fill and vent the system and open all Isolation Valves Ensure wiring has continuity and is securely connected Replace Water Pressure Switch | Details |
| FLOW/RETURN REVERSED | Flow/Return Reversed Show causes & actionsEngineer action Check if Flow Thermistor correctly clipped to pipe Replace Flow Thermistor | Details |
| NO WATER FLOW FAULT | No Water Flow Fault Show causes & actionsLikely causes
Engineer action Fill and vent the system and open all Isolation Valves Ensure wiring has continuity and is securely connected Replace Main PCB Replace Pump | Details |
| PCB REPLACED | PCB Replaced Show causes & actionsUser action Restart boiler by pressing RESTART | Details |
| PUMP ROTOR BLOCKED | Pump Rotor Blocked Show causes & actionsEngineer action Unblock Pump | Details |
| NO CONNECTION TO PRIMARY PCB | No Connection To Primary PCB Show causes & actionsLikely causes
User action Turn power Off and On Engineer action Replace the wiring from the Primary PCB to the User Interface PCB | Details |
| PUMP LOW VOLTAGE FAULT | Pump Low Voltage Fault Show causes & actionsEngineer action Check Pump wiring Replace Pump | Details |
| NO CH BUT DHW OK | No CH But DHW Ok Show causes & actionsLikely causes
Engineer action Turn Central Heating Dial Clockwise Ensure that the Timer and Room Thermostat are calling for heat Open the Radiator Valves Consult Electronic Programmable Room Stat Fault Finding Instructions There is no voltage from the Timer/Room Stat. This is not a boiler fault. Ensure voltage is supplied to the boiler by correcting external wiring Check wiring from PCB to Diverter Valve Replace Diverter Valve | Details |
| NO DHW BUT CH OK | No DHW But CH Ok Show causes & actionsLikely causes
Engineer action Ensure cold inlet and hot water outlet are not reversed Re-connect wiring Remove Turbine and clear any debris, is DHW OK? Fit new turbine Adjust flow rates to achieve 35°C temperature rise and check filter fitted in turbine is not blocked with debris Replace or reconnect as appropriate Re-engage diverter valve head and secure clip to waterset Replace Diverter Valve body | Details |
| BLANK DISPLAY | Blank Display Show causes & actionsLikely causes
Engineer action Supply power to the boiler Connect the wiring from the terminal block to the main PCB securely Replace the wiring from the boiler terminal block to the Main PCB Connect the cable from the main PCB to the user interface PCB securely Replace cable from main PCB to user interface PCB Replace Main PCB Replace main PCB | Details |
| FLOW TEMPERATURE SETPOINT CANNOT BE INCREASED TO 80°C | Flow Temperature Setpoint Cannot Be Increased To 80°C Show causes & actionsEngineer action Ensure Flow Temp is not limited within Installer Mode (see Section 2.28) | Details |
| FLOW/RETURN THERMISTOR FAULT | Flow/Return Thermistor Fault Show causes & actionsEngineer action 1. Check flow and return thermistors securely clipped to pipes. 2. Check flow & return thermistors (use values from Section 4.7) | Details |
Patterns that group across the manufacturer's fault-code table. Each entry links to the full code listing further down the page.
Engineer: Restart Boiler Fill and vent the system and open all Isolation Valves, then Restart the Boiler Check the Flow and Return Thermistors (refer to Sections 4.7 & 4.9) Replace the Pump, then Restart the Boiler
Triggered by fault code OVERHEAT LOCKOUT.
User: Check other gas appliances work If pre-payment meter check credit If not, contact gas supplier Restart boiler.
Engineer: Check the Detection Electrode and associated Harness for continuity, visual condition and position (refer to Section 3.16). Check if the Condensate Pipe is Blocked. Check Gas Supply and rectify fault Check wiring from Gas Valve to PCB and replace if necessary, otherwise replace the main PCB Replace Gas Valve Replace Spark Generator and Harness as necessary Replace Ignition Electrode and associated Harness as necessary Replace Gas Valve
Triggered by fault code IGNITION LOCKOUT.
User: Press RESTART, then power cycle the boiler.
Engineer: Replace the primary PCB Replace the wiring from the PCB to the thermal fuse Replace the heat exchanger
Triggered by fault code THERMAL FUSE LOCKOUT.
Engineer: Check the Detection Electrode and associated Harness for continuity, visual condition and position. Check if the Condensate Pipe is blocked. Check if the Flue is blocked. Replace as necessary Check Gas Supply and rectify fault Check wiring from Gas Valve to PCB and replace if necessary, otherwise replace the main PCB Replace Spark Generator and Harness as necessary Replace Ignition Electrode and associated Harness as necessary Replace Gas Valve
Triggered by fault code FLAME LOSS.
User: Turn power off and on
Triggered by fault code TOO MANY RESETS.
Diagnostic checklists from engineer-submitted Ideal faults, with step-by-step checks and safety notes.
The Ideal Logic MAX Combi C24 is displaying an 'Overheat Lockout' fault (sometimes referred to as L1), with no heating or hot water and the…
The Ideal Vogue Max Combi 26 displaying 'IGNITION LOCKOUT' indicates that the boiler has failed to ignite after several attempts and has…
Common questions from engineers and homeowners about the Ideal Vogue Max Combi 40.
We hold the Ideal Vogue Max Combi 40 manual — and every other UK boiler and heat pump brochure. Sign up and pull any model up from your phone, on the job.
Sign up to access brochuresTag it before you leave. Next scan shows every service, fault and part change — and the AI diagnostic tool is free on every tag you fit.
Specifications on this page are extracted from the manufacturer brochure. Always cross-check against the latest datasheet before commissioning or quoting. Last updated 28 June 2026.