Ideal Logic Max Combi C24 fault Overheat Lockout 1/4: Customer's got no heating or hot water, boiler's showing 0 bar and…
Published 28 June 2026 · Generated by BoilerTag's diagnostic AI from an engineer's real-world submission
One of 13 real-world fault checklists on BoilerTag, across 5 boiler makes.
Most likely cause
The Ideal Logic MAX Combi C24 is displaying an 'Overheat Lockout' fault (sometimes referred to as L1), with no heating or hot water and the pressure gauge at 0 bar. This fault indicates the boiler temperature has exceeded safe operating limits, shutting down as a safety precaution. Common causes include low water pressure, poor circulation, air in the system, a blocked heat exchanger, or closed valves. The 0 bar pressure reading is a critical factor, as the boiler will not operate below 0.3 bar. There is also a safety recall for some Ideal Logic 2 Combi and System Boilers (including MAX models) regarding a risk of fire due to dry operation. It is crucial to check if the specific boiler is affected by this recall.
The engineer's report
A gas engineer submitted this case through BoilerTag's free fault diagnostic tool, working on a Ideal Logic Max Combi C24 displaying fault code Overheat Lockout 1/4. They described the behaviour they were seeing on site as follows:
“Customer's got no heating or hot water, boiler's showing 0 bar and the 'Overheat Lockout' fault. It's completely cold, no noises. CH pump not running.”
Before requesting the AI diagnostic, the engineer had already worked through the following checks:
“Checked the filling loop, made sure all isolation valves were open, looked at the system filter, and confirmed radiator valves were open. Noticed the pressure gauge was at zero.”
BoilerTag's diagnostic AI then cross-checked manufacturer documentation and common trade knowledge to produce the prioritised checklist below.
Diagnostic checklist
Email me this checklist
Get the full Ideal Logic MAX Combi C24 diagnostic — steps, safety notes and parts — sent to your inbox to keep or share on site.
More Ideal fault codes
Sources
The AI cross-checked the following manufacturer and trade sources while producing this checklist.
Tag it once. Get rebooked every year.
Stick a BoilerTag on the boiler. The homeowner scans the QR when the service is due — your name and number are right there. Your first 12 tags are free.
Get 12 free BoilerTagsThis checklist is provided for reference only. Always follow manufacturer documentation and stay within Gas Safe scope. BoilerTag does not replace a qualified engineer's own judgement.
Fixed a fault the hard way? Add your fix — help the next engineer →