Baxi fault diagnostics
Baxi 824 Combi 2 — E.04.10
The Baxi 824 Combi 2 displaying fault code E.04.10 indicates that the burner has failed to ignite after four attempts. This is a common fault that can be caused by several issues, including a gas supply problem, a frozen condensate pipe, or a fault with the ignition electrodes or flame sensor. The boiler is designed to lock out for safety reasons when this fault occurs. The pressure gauge reading of 1.5 bar is normal, so low system pressure is unlikely to be the cause in this instance.
Published 21st April 2026
Baxi 800
The Baxi 800 boiler intermittently heating without a fault code can be attributed to several common issues, including low system pressure, circulation problems, or issues with the thermostat or diverter valve. While no specific fault code was provided, common Baxi fault codes related to heating issues include E119 (low pressure) and E125 (circulation fault). It's crucial to address these systematically, prioritising safety and checking the simplest causes first.
Published 20th April 2026
Baxi 100HE — Ignition Lockout
The Baxi 100HE displaying an 'Ignition Lockout' fault, with no heating or hot water and no noises, indicates the boiler has failed to ignite after several attempts and has entered a safety lockout state. This is a common fault for Baxi 100HE models, particularly after cold weather, and can be caused by various issues including a blocked condensate trap, faulty ignition components, or issues with the gas supply or fan operation.
Published 12th April 2026
Ideal fault diagnostics
Ideal Logic
The Ideal Logic + Heat boiler failing to ignite, despite new spark generator and electrode, 37mbar standing pressure dropping to 34mbar on ignition attempt, and 233V DC to the gas valve, points towards a persistent ignition lockout. Common causes for ignition lockout (often indicated by an L2 fault code on Ideal Logic boilers) include issues with gas supply, gas valve, flue/air intake, condensate, flame rectification, or the PCB. Given the steps already taken, further investigation into gas valve resistance, flame rectification, and potential PCB faults is crucial.
Published 22nd July 2026
Ideal Logic MAX Combi C24 — Overheat Lockout 1/4
The Ideal Logic MAX Combi C24 is displaying an 'Overheat Lockout' fault (sometimes referred to as L1), with no heating or hot water and the pressure gauge at 0 bar. This fault indicates the boiler temperature has exceeded safe operating limits, shutting down as a safety precaution. Common causes include low water pressure, poor circulation, air in the system, a blocked heat exchanger, or closed valves. The 0 bar pressure reading is a critical factor, as the boiler will not operate below 0.3 bar. There is also a safety recall for some Ideal Logic 2 Combi and System Boilers (including MAX models) regarding a risk of fire due to dry operation. It is crucial to check if the specific boiler is affected by this recall.
Published 28th June 2026
Ideal Vogue Max Combi 26 — IGNITION LOCKOUT
The Ideal Vogue Max Combi 26 displaying 'IGNITION LOCKOUT' indicates that the boiler has failed to ignite after several attempts and has entered a safety lockout mode. This is a common safety feature to prevent dangerous situations. The boiler will not make any noises, provide hot water, or heating until the fault is cleared and the system is reset. Common causes include issues with the gas supply, a blocked condensate pipe, or faulty ignition components.
Published 10th April 2026
Glow Worm fault diagnostics
Glow Worm Energy 25c — F.32
The Glow Worm Energy 25c displaying fault code F.32, with the fan cycling erratically and making a struggling humming noise, indicates an 'air pressure issue' or 'fan speed outside the tolerance values'. This is often caused by a fan malfunction, blocked air intake/flue, or a faulty Hall sensor. The intermittent nature becoming constant suggests a component is failing completely.
Published 12th May 2026
Glow Worm Energy 25c — F.28
The Glow Worm Energy 25c displaying an F.28 fault code indicates an ignition failure. This means the boiler is attempting to ignite but is unable to establish a flame. The clicking noise you hear is likely the boiler trying to spark. Common causes range from simple gas supply issues to more complex component failures within the ignition system. The pressure gauge reading of 1 bar is within the normal cold operating range, so low pressure is unlikely to be the primary cause of this specific fault.
Published 24th April 2026
Vaillant fault diagnostics
Vaillant ecoTEC plus 610 — F.028
The Vaillant ecoTEC plus 610 displaying fault code F.028 indicates an ignition failure, meaning the boiler failed to ignite or detect a flame during startup. This leads to the boiler locking out as a safety measure. Common causes include issues with the gas supply, a blocked or frozen condensate pipe, a faulty ignition system (electrode, lead, transformer), or a defective gas valve or PCB. The clicking sound before lockout is consistent with the boiler attempting ignition. The normal pressure reading suggests the issue isn't related to low system pressure.
Published 22nd June 2026
Vaillant ecoTEC plus 610 — F.040
The Vaillant ecoTEC plus 610 displaying fault code F.040 indicates that the air ratio is too low, often due to a fault in the flue gas route, recirculation, or a blockage. It can also be caused by a blocked air intake pipe or condensate in the combustion chamber due to a blocked condensate discharge. The symptoms of the fan kicking in, ignition sequence attempting, but locking out before ignition, align with this fault code, suggesting an issue preventing proper combustion. Given the intermittent nature and occurrence when firing from cold, it points towards a component that might be struggling to perform correctly under initial demand. The gas tightness check and clear flue terminal/condensate trap are good initial steps, but further investigation into the air/flue system and ignition components is necessary.
Published 2nd June 2026
Worcester fault diagnostics
Worcester Greenstar 12i System — Heat exchanger overheat
The Worcester Greenstar 12i System displaying a "Heat exchanger overheat" fault code indicates the boiler's safety systems have activated due to excessively high temperatures within the heat exchanger. This is a critical safety lockout designed to prevent damage to the appliance. Common causes include poor water circulation, a blocked heat exchanger (often due to limescale or sludge), airlocks, or a faulty pump. The intermittent nature suggests a developing issue rather than a sudden component failure. The pressure reading of 1.5 bar is within the normal operating range, so low pressure is unlikely to be the primary cause.
Published 3rd June 2026
Worcester Greenstar 12i System — Ignition lockout
The Worcester Greenstar 12i System displaying an 'Ignition lockout' fault indicates that the boiler has attempted to ignite but failed to detect a flame, leading to a safety shutdown. This is a protective mechanism to prevent unsafe operation. The boiler will not restart until the underlying fault is identified and resolved, and the boiler is manually reset. Repeatedly resetting the boiler without addressing the cause can lead to further damage to components like the PCB and ignition parts.
Published 8th April 2026
Intergas fault diagnostics
worcester fault diagnostics