Published 10 April 2026 · Generated by BoilerTag's diagnostic AI from an engineer's real-world submission

One of 13 real-world fault checklists on BoilerTag, across 5 boiler makes.

Most likely cause

The Ideal Vogue Max Combi 26 displaying 'IGNITION LOCKOUT' indicates that the boiler has failed to ignite after several attempts and has entered a safety lockout mode. This is a common safety feature to prevent dangerous situations. The boiler will not make any noises, provide hot water, or heating until the fault is cleared and the system is reset. Common causes include issues with the gas supply, a blocked condensate pipe, or faulty ignition components.

The engineer's report

A gas engineer submitted this case through BoilerTag's free fault diagnostic tool, working on a Ideal Vogue Max Combi 26 displaying fault code IGNITION LOCKOUT. They described the behaviour they were seeing on site as follows:

hi my boiler is showing IGNITION LOCKOUT and then it says Ignition Lockout under it. it doesnt make any noises at all, no beeps or clicks or anything. just totally silent. there's no hot water or heating. the display just shows that message constantly. it doesnt even try to do anything, just stuck on that screen. the pressure gauge on the front looks ok, its in the green zone. it happened all of a sudden this morning, was fine yesterday.

Before requesting the AI diagnostic, the engineer had already worked through the following checks:

ive tried pressing the reset button a few times but it just comes straight back to the same message. checked the condensate pipe outside & it looks clear. also checked other gas things in the house & they're working fine so it's not the gas supply i think. my prepayment meter has plenty of credit too.

BoilerTag's diagnostic AI then cross-checked manufacturer documentation and common trade knowledge to produce the prioritised checklist below.

Diagnostic checklist

Email me this checklist

Get the full Ideal Vogue Max Combi 26 diagnostic — steps, safety notes and parts — sent to your inbox to keep or share on site.

More Ideal fault codes

Browse all Ideal fault diagnostics →

Sources

The AI cross-checked the following manufacturer and trade sources while producing this checklist.

Tag it once. Get rebooked every year.

Stick a BoilerTag on the boiler. The homeowner scans the QR when the service is due — your name and number are right there. Your first 12 tags are free.

Get 12 free BoilerTags

This checklist is provided for reference only. Always follow manufacturer documentation and stay within Gas Safe scope. BoilerTag does not replace a qualified engineer's own judgement.

Fixed a fault the hard way? Add your fix — help the next engineer →