Samsung
The Samsung RC160MHXGA is a 16 kW monobloc air-source heat pump, utilising R410A refrigerant and capable of a 70°C maximum flow temperature.
The Samsung RC160MHXGA is an air-to-water monobloc heat pump, part of Samsung's control unit series. This page provides technical information and operational insights for UK heating engineers. The RC160MHXGA, inferred to be a 16 kW unit, utilises R410A refrigerant. It is designed for domestic heating applications, offering a maximum flow temperature of 70°C. This reference details its specifications, available variants, and general operational characteristics relevant for installation and servicing.
Stick a QR tag on the case, scan it on every service and give your customer a permanent, shareable service history they can pull up from any phone.
Permanent, shareable service history
One QR scan on the boiler surfaces every previous fault, part change and visit — no paperwork to dig out.
Free AI fault diagnostics, built in
Every tag you fit unlocks the AI diagnostic tool for that exact model — paste a fault code, get a ranked cause list.
Your name on the boiler forever
When the next service or breakdown comes around the homeowner scans and sees your number first.
First 12 BoilerTags are free
Tag every install and service you do from now on — the subscription only kicks in once you scale past your first dozen.
Diagnosing a fault on a Samsung Air to Water Heat Pump -Mono Control Unit right now?
Try the free AI fault diagnostics tool — no signup needed.
Full technical specifications extracted from the manufacturer brochure. Empty sections are hidden.
The Samsung RC160MHXGA is identified as an air-to-water heat pump, specifically a monobloc control unit within Samsung's heating appliance portfolio. This model, alongside its variants, is designed for domestic heating applications in the UK. Per the manufacturer's documentation, the RC160MHXGA is inferred to be a 16 kW capacity unit, making it suitable for a range of residential properties requiring robust heating solutions, particularly those with higher heat demands.
This monobloc configuration integrates all primary refrigeration components into a single outdoor unit. This design simplifies installation as it only requires water pipe connections to the indoor heating system, eliminating the need for F-Gas qualified engineers to handle refrigerant lines on-site for the primary installation, though F-Gas certification is still required for any work involving the refrigerant circuit itself. The system operates using R410A refrigerant, a common choice in air-source heat pumps, known for its thermodynamic properties. While specific efficiency ratings such as Seasonal Coefficient of Performance (SCOP) are not detailed in the available documentation, the unit is capable of delivering a maximum flow temperature of 70°C. This high flow temperature capability can be advantageous for retrofitting into properties with existing radiator systems that may not be optimised for lower flow temperatures typically associated with heat pumps.
Operational characteristics include an automatic defrost function, ensuring reliable performance during colder UK ambient conditions by preventing ice build-up on the outdoor coil. This feature is crucial for maintaining efficiency and consistent heating output throughout the winter months. The product family includes several variants, such as the RC120MHXGA (inferred 12 kW), RC140MHXGA (inferred 14 kW), and RC090MHXEA (inferred 9 kW), all utilising R410A refrigerant. These model numbers suggest a clear progression in heating capacity, allowing engineers to select an appropriate size based on the property's heat loss calculations and specific requirements.
Given that the provided information is primarily from a user manual, detailed technical specifications, such as precise coefficient of performance (COP) values at various operating points, sound power levels, or specific electrical requirements, are not extensively documented. Installers should consult comprehensive datasheets or Samsung's official technical resources for full performance data and compliance information. This appliance is intended for professional installation and servicing by qualified UK heating engineers. Understanding its fundamental design, inferred operational parameters, and the implications of its monobloc R410A configuration is crucial for effective deployment and long-term maintenance in the diverse UK housing stock.
Common questions from engineers and homeowners about the Samsung Air to Water Heat Pump -Mono Control Unit.
We hold the Samsung Air to Water Heat Pump -Mono Control Unit manual — and every other UK boiler and heat pump brochure. Sign up and pull any model up from your phone, on the job.
Sign up to access brochuresTag it before you leave. Next scan shows every service, fault and part change — and the AI diagnostic tool is free on every tag you fit.
Specifications on this page are extracted from the manufacturer brochure. Always cross-check against the latest datasheet before commissioning or quoting. Last updated 30 April 2026.